Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA

    Buy cheap Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA from wholesalers
     
    Buy cheap Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA from wholesalers
    • Buy cheap Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA from wholesalers

    Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA

    Ask Lasest Price
    Brand Name : Uchi
    Model Number : OBV-I25-2
    Certification : CE / SGS / ISO9001
    Price : Negotiate
    Payment Terms : T/T, L/C, Western Union
    Supply Ability : 60000 pieces per month
    Delivery Time : 5-15 days after payment
    • Product Details
    • Company Profile

    Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA

    Multilayer Graphite Ignition Structure Type I SPD Surge Protection Device Iimp 25kA

    Uc(maximum continuous operating voltage)275V
    Iimp(impulse discharge current for class I test)25kA
    In(nominal discharge current for class II test)100kA
    Up(voltage protection level)≤2.0kv
    response time≤100ns
    Housing Materialthermoplastic material
    Housing self-extinguishing classUL94_V0
    Temperature range-40℃+80℃
    Humidity range5%RH~95%RH
    Elevational≤3000m
    Method of connecting wiremultiple
    (Connect In Parallel )
    Mounting methodDIN:35mm
    IP(degree of protection of enclosure)IP20
    Application standardGB18802-1;IEC61643-1

    Product features:

    1. Multilayer graphite ignition structure
    2. Integrated surge protector unit
    3. Withstand up to 50kA (10/350 μs) of lightning strike
    4. Action response time is less than 100ns


    Surge protection device T1,T2,T3 relative info

    1. According to the definition of IEC61643.1 standard: base on the application environment and test requirements, it can be divided into class I test, class II test and class III test, which are identified as "T1", "T2" and "T3". The test waveforms weremaximum impulse current Iimp (10/350μs); In (8/20μs), impulse voltage of 1.2/50μs. The energy difference between T1 and T2 is huge, T1 being hit directly and T2 being affected by the shock wave

    2. From the point of view of the product analysis, as to T1, T2 and T3 level lightning protection device can not be used "advantage" and "disadvantage" to distinguish good or bad, because these lightning protection device each with different use. These can be compared according to the environment and energy used. T1 is applied environment LPZ0A or LPZ0B and LPZ1 interface area, used for lightning high incidence area, lightning current intensity is large level I protection. According to the building lightning protection code, Class I buildings should have T1 SPD of no less than 12.5kA (10/350μs), and local laws and regulations will have more stringent requirements, T1 SPD impulse current will be larger, and T2 SPD should not be less than 60kA (8/20μs). The SPD installation of II and III buildings is different.

    3. Class T2 and Class T3 should be installed base on the way of gradual weakening of lightning protection energy and the required configuration of insulation and voltage resistance of protection equipment. For example, the T2 class and T3 class SPD can achieve low residual pressure and more effective protection for equipment. These lightning protection devices have different uses, can be configured according to the appropriate situation of lightning protection device


    Quality Multilayer Graphite Ignition Structure Type I Surge Protection Device SPD Iimp 25kA for sale